Light gauge steel framing designer (free LGS house design tool)

Light gauge steel framing designer

Enter a single-storey house and its climatic loads, and get the cold-formed steel framing designed: stud, header and truss sections, the piece count and steel mass, and the utilisation ratio of every member and connection check to AISI S100-16 and AISI S240-20 under NBC 2020 loads.

Free tool · cold-formed steel · Canada

House

Out-to-out of the wall framing. The front and back walls run along the length; the trusses span the shorter side.

Openings

Each row: wall, type, distance from the left end of the wall seen from outside, width and sill height, in m. Keep 0.3 m to each corner and between openings. Window tops are at 2.134 m.

Loads at the site

Ground snow Ss, rain Sr and the 1-in-50 hourly wind pressure q50 for your location, from NBC 2020 Division B Appendix C, Table C-2. The defaults are for Barrie, Ontario.
Spectral acceleration in g, 2% in 50 years, site designation X450 (site class C), from the NRCan 2020 seismic hazard tool.
Dead loads
Roofing, sheathing and trusses on plan; ceiling finishes and insulation; exterior wall build-up.
Your inputs are sent to the Structomat design server, designed in a few seconds and not stored.

Press Design the framing. The sample house is already filled in.

What you get

  • A framed house, not a rule of thumb. Studs and tracks in line with Fink roof trusses, a box header with jack and king studs over every opening, full-height gable walls and bridging, then the loads, the analysis and a check of every member group and connection.
  • Sections sized for you. The lightest SSMA C-sections that pass are chosen for the studs, headers, truss chords and webs.
  • Every ratio. 60 to 70 checks with their utilisation: truss chords, webs, heel and ridge connections, studs under axial load and wind, headers, gable walls, shear walls, the roof diaphragm, uplift and overturning.

This version covers a single-storey house with a rectangular plan and a gable roof on a concrete slab, in Canada, with no interior load-bearing walls. The result is a preliminary design: anchors, hold-downs and foundations are not designed, and nothing here is signed. See a sample house with its full calculation report.

Need it signed for construction?

Send the drawings and the location. You get the calculation report, wall framing elevations, truss details, a material list and an IFC model, reviewed and signed by a licensed partner engineer. The first job is US$100.

Ask for a quote See pricing